Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM03689
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/10/2004 | FRAMING | Approved | IVRS - Inspection :* | |
11/08/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) LAST INSPECTION, LEAVE F/PLACES SPECS ? 2) BANG PLATE AT BLACK CABLE GARAGE S. WALL 3) 1 1/2" CLR TO COMBUSTIBLE AT FLU 4) SECURE FIRE STOPS |
|
11/05/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) NEED NUTS ON GARAGE HOLDOWNS 2) NEED FIRE STOPS ON FIREPLACE 3) NEED INSTALLATION INSTRUCTIONS FOR FIREPLACE 4) BOLTS MISSING BY GARAGE DOOR AND NORTH GARAGE WALL |