Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 01/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 8D NAILS 6" ON CENTER SPACING ROOF SHEATHING INTO BIRD BOARD BLOCKS 2) REPLACE DAMAGED STUDS AT RSP4'S AND H2.5'S 3) STRAP CONDENSATE AND PLUMBING EXTERIOR |
|
| 01/07/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS NOT CORRECTED 2) STOPPED INSPECTION |
|
| 12/30/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio |
|
| 12/28/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPLACE ALL DAMAGED CLIPS/TRUSS REPAIR NOT PER DETAIL 2) NAIL PROTECT CONDENSATE LINE FROM OUTSIDE 3) NAIL PROTECT ELECTRICAL FROM OUTSIDE AT PANEL 4) DBL TOP PLATE AT NORTH WALL NOT STAGGERED PER CODE 5) STOPPED INSPECTION |
|
| 12/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FROM LAST INSPECTION: ALL SHEAR WALLS REQUIRE A TRANSFER CONNECTION SOME SHEAR WALLS ON THIS PLAN HAVE NOT BE LABELED FOR CROSS SECTION TO MATCH TRANSFER DETAILS ON DETAIL PAGE 3) 24" X 24" OSB GUSSET REPAIR TO TWO (DO1P) TRUSSES, ORIGINAL GUSSET, TO SMALL INSTALL 24" X 24" GUSSET 4) 3RD TRUSS STILL MISSING METAL GUSSET PLATE, MARKED ON FLOOR. ALL FOUR D01P TRUSSES ARE THE SAME EXCEPT, ONE SIDE HAS A SMALLER METAL GUSSET PLATE, SEE TRUSS DRAWINGS, TWO ARE INSTALLED BACKWARD 5) FRONT COLUMN P.A. STRAP NOT INSTALLED CORRECTLY INSTALL ALTERNATE |
|
| 12/21/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) PLEASE WRITE OPTIONS ON PERMIT CARD EXAMPLE D01P TRUSSES AT PORCH OPTION 2) HAVE ENGINEER LABEL WHERE SHEAR TRANSFER DETAILS GO 3) NEED 24" X 24" GUSSETS ON TWO TRUSSES DO1P, BOTH SIDES PER DETAIL, INSTALLED BACKWARD, MISSING METAL GUSSET AT 3RD TRUSS NEXT TO EXHAUST FAN, DO1P TRUSS 4) P.A. STRAP AT FRONT COLUMN NEED A ALTERNATE EPOXY BOLT INSTALLED |
|
| 12/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO LOT NUMBER POSTED 2) SILL PLATE NOT BEARING ON CONCRETE AT GARAGE TRIMMERS 3) LIST PLAN AND ELEVATION ON INSPECTION CARD. CANNOT TELL WHICH ELEVATION APPLIES. INSPECTED PER ELEVATION "A" 4) HOLDOWN AND AB AT ENTRY POST ? BEYOND USE 5) PROVIDE TRUSS REPAIR DOCUMENTS |
|
| 12/16/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO TRUSS CALC'S ON SITE 2) FRONT POST HAS AN OVERSPALLED HOLDOWN 3) REAR POST HOLDOWN NOT NAILED 4) PROVIDE ENGINEERING AND CITY APPROVED OSB GUSSET REPAIR FOR TWO TRUSSES REAR OF HOUSE 5) STOPPED INSPECTION, HAVE SUPERVISOR AND TRADES WALK HOUSE BEFORE RECALL |