| 12/28/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) REPLACE ALL DAMAGED CLIPS |
|
| 12/22/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection :DENIED-1) NO LOT NUMBER OR ADDRESS. 2) REPLACE ALL DAMAGED CLIPS. 3) NAILS AT NORTH EAST SHEER HAVE OVER PEN?TRADES(?) REPLACE ALL PANELS. | |
| 12/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NO LOT NUMBER OR ADDRESS 2) GARAGE ENTRY MUST BEAR ON FOUNDATION 3) LIST ELEV AND PLAN ON PERMIT AND SORT TRUSS CALC'S 4) A01A NOT BRACED PER PLAN 5) A01AE NOT BRACED PER PLAN 6) B01 PLAN MISSING 7) B01E PLAN MISSING 8) A01 P NOT FULL BEARING MID POINT, SHIM 9) HOLDOWN MISSING AT REAR OF HOUSE 10) ROOF SAGGING OVER ? WINDOWS 11) 10/DT1 NOT NAILED THRU ROOF 12) 6/DT1 NOT NAILED THRU ROOF 13) STOPPED INSPECTION |
|
| 12/16/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE BY TERRY |