Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM03616

Parcel: 111051670

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM03616

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/07/2004 FRAMING Approved IVRS - Inspection :*
10/05/2004 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*/ 1) TRUSS BRACING ABOVE DEAD WOOD-SEE TRUSS DRAWING NOTES 2) NO DWV WATER TEST 3) NON BEARING WALLS CANNOT BE IN CONTACT WITH SCISSOR TRUSSES. PROVIDE CLEARANCE FOR DEFLECTION 4) 3 PT BEARING TRUSSES MUST BEAR ON MID-POINT 5) CLIP ALL BEARING POINTS 6) BATHS LAV DIRTY ARM CANNOT BE HIGHER THAN 1 1/2" OR 42" IN LENGTH 7) MASTER BATH LAV. S. TRAPPED 8) W/C SUPPLY NOT SECURE 9) TRAP AND TRAP ARM MUST BE SAME SIZE 10) RANGE POWER NOT IN 11) DUCTWORK NOT PER PLAN. PLAN CALLS FOR METAL DUCTWORK FLEX USED. BUILD PER PLAN OR REVISE PLAN TO AS-BUILT 12) GAS LINES NOT INSTALLED 13) STOPPED INSPECTION TOO MANU ITEMS