Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM03616
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/05/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) TRUSS BRACING ABOVE DEAD WOOD-SEE TRUSS DRAWING NOTES 2) NO DWV WATER TEST 3) NON BEARING WALLS CANNOT BE IN CONTACT WITH SCISSOR TRUSSES. PROVIDE CLEARANCE FOR DEFLECTION 4) 3 PT BEARING TRUSSES MUST BEAR ON MID-POINT 5) CLIP ALL BEARING POINTS 6) BATHS LAV DIRTY ARM CANNOT BE HIGHER THAN 1 1/2" OR 42" IN LENGTH 7) MASTER BATH LAV. S. TRAPPED 8) W/C SUPPLY NOT SECURE 9) TRAP AND TRAP ARM MUST BE SAME SIZE 10) RANGE POWER NOT IN 11) DUCTWORK NOT PER PLAN. PLAN CALLS FOR METAL DUCTWORK FLEX USED. BUILD PER PLAN OR REVISE PLAN TO AS-BUILT 12) GAS LINES NOT INSTALLED 13) STOPPED INSPECTION TOO MANU ITEMS |