Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2004 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 12/08/2004 | PLUMBING - GAS PRESSURE TEST | Cancelled | IVRS - Ri canceled | |
| 12/07/2004 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | 1) LEAK ON WASHER P-TRAP 2) LEAK IN 1ST FLOOR LAV 3) BLOCK ALL MECH VENTS 4) NEED MINIMUM 60 DEGREE ON H20 HTR FLUE 5) SMALL HEADER HANGERS BOTH ENDS OF STAIRS. FILL HOLES IN HANGERS WITH NAILS 6) PUT MORE NAILS IN FRONT PORCH 2 X 4 LEDGER 7) WRONG SIZE NAILS IN GIRDER TO GIRDER CONNECTION ROOF 8) SHEET ROCK STACKED PARALELL WITH FLOOR JOISTS (DANGEROUS) 9) BACKING 2ND FLOOR TUB SIDES 10) 2ND FLOOR H20 HETR FLUE MINIMUM 60 DEGREE 11) 2ND FLOOR BOTH TUBS DIVERTER NOT SECURED 12) ALL CONCENTRATED LOADS=GIRDER FROM 2ND FLOOR DOWN TO 1ST FLOOR DBL STUDS AND BLOCKS FROM TOP TO BOTTOM 13) GAS BOND CLAMP 14) GAS TEST/DRAIN WASTE VENT OK |