Permit: T04CM03612

Parcel: 140375530


Addresses:

5910 E CEDARBIRD DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/14/2005 FRAMING Approved IVRS - Inspection :*
01/25/2005 FRAMING Partial Approval IVRS - Inspection :*
01/21/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DWV'S AND WATER LINES OK
2) SUPT ALL PLUMBING
3) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR AND INTO ATTIC SPACE
4) FIRE BLOCK MISSING AT KITCHEN HOOD VENT
5) PROVIDE CITY OF TUCSON APPROVED DOCUMENTS FOR TRIPPLE GIRDER AND KITCHEN DBL TOP PLATE FIX
01/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) DWV AND WATER LINES OK
2) STAIRS NOT TO CODE
3) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR AND INTO ATTIC SPACE
4) HORIZONTAL WATER LINES RUNS MUST HAVE 1 1/2 CLEARANCE FROM EDGE OF TRUSS
5) NAIL PROTECT T & P LINE
6) STAIRS STRINGERS NOT PROPERLY FIRE BLOCKED
7) NEED ALL ENGINEERING APPROVED BY CITY OF TUCSON FOR THIS ADDRESS
8) PROVIDE SMOKE DETECTOR OUTSIDE BEDROOMS
9) ABS NOT SUPPORTED IN ATTIC SPACE
10) CHECK FURNACE AREA AND PROVIDE 1" CLEARANCE B-VENT FROM COMBUSTIBLES
01/12/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED ON SITE BY LOURDES