Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/14/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/25/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 01/21/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DWV'S AND WATER LINES OK 2) SUPT ALL PLUMBING 3) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR AND INTO ATTIC SPACE 4) FIRE BLOCK MISSING AT KITCHEN HOOD VENT 5) PROVIDE CITY OF TUCSON APPROVED DOCUMENTS FOR TRIPPLE GIRDER AND KITCHEN DBL TOP PLATE FIX |
|
| 01/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DWV AND WATER LINES OK 2) STAIRS NOT TO CODE 3) SEAL PENETRATIONS FROM 1ST TO 2ND FLOOR AND INTO ATTIC SPACE 4) HORIZONTAL WATER LINES RUNS MUST HAVE 1 1/2 CLEARANCE FROM EDGE OF TRUSS 5) NAIL PROTECT T & P LINE 6) STAIRS STRINGERS NOT PROPERLY FIRE BLOCKED 7) NEED ALL ENGINEERING APPROVED BY CITY OF TUCSON FOR THIS ADDRESS 8) PROVIDE SMOKE DETECTOR OUTSIDE BEDROOMS 9) ABS NOT SUPPORTED IN ATTIC SPACE 10) CHECK FURNACE AREA AND PROVIDE 1" CLEARANCE B-VENT FROM COMBUSTIBLES |
|
| 01/12/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED ON SITE BY LOURDES |