Permit: T04CM03605

Parcel: 136326490


Addresses:

4377 S SKY HIGH PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/10/2005 FRAMING Approved IVRS - Inspection :*
05/31/2005 FRAMING Not ready for Inspection IVRS - Inspection :* 1) REPAIR TJI'S PER ENGINEER DOCUMENT. 2) SEE NOTES FROM 5/25 INSPECTION.
05/25/2005 FRAMING Partial Approval IVRS - Inspection :*
1) H20 SERVICE CALC 150' TO N/HOSE BIBS THAT'S 54 UNITS THE MOST REMOTE FIXTURE. NEED H20 PIPING PLAN
2) TRUSS JOISTS TO BE FIXED
3) HALL BATH LAV STUD BROKEN
4) 42" ON 1 1/2" TRAP ARM FROM WIER TO INLET USE 45" OFF SET OVER TO REDUCE LENGTH TRAP TO BE SAME SIZE AS TRAP ARM
5) OUTLETS AT PENINULAR, NOT ALLOWED UNDER OVERHANG
05/16/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) ENGINEERING FROM TJI'S, I DON'T UNDERSTAND WHAT IT STATES, PROBLEM IS THIS 4" HOLE DRILLED IN END OF JOIST APPROX 7'-1/2" FROM END
2) NO GAS PRESSURE-ZERO ON GAGE
3) NEGATIVE PITCH LAV. TRAP ARM HALL BATH NORTH AND STUD BROKEN BLOCKS-NOT IN LINE
4) MASTER BATH, LAV WET VENTING TOILET, WET VENTING IS FOR TRAP ARMS ONLY NOT DRAINS
5) WINDOWS NOT INSTALLED
6) SECURE JACUZZI CIRCUIT
7) SECURE ALL FIREPLACE FLUES, INSTALL METAL FIRESTOPS AT DROP CEILINGS SECURE FLEX GAS LINE AWAY FROM FIREPLACES
8) ROMEX AT FIREPLACE NOT SECURED, BANG PLATE ROMEX AT HEARTH
9) FIREBLOCK AT FIREPLACE STUD SPACES TOP OF WALL
10) OUTLETS NOT ALLOWED UNDER COUNTER (KITCHEN)
11) SOUTH TUB DIRT IS WET AT TUB SHOW AREA, FILL TUB DIRT SHOULD BE DRY, LOOSE BANG PLATE AT LAV. VENT, NO H20 IN SOUTH TUB 2ND TUB, 3RD TUB SOUTH-NO H20
12) DRYER DUCT BROKEN
13) NO H20 TEST ON DWV
14) NEED CORRECTIONS ON H20 SUPPLY PLUMB PAGE, HOW FAR IS METER FROM HOSE, 54 UNITS IN . I MEASURED ? FROM GARAGE WALL TO NORTH FURNACE ROOM WITH TWO H20 HTRS, 5 BATHS, 1" H20 SERV IS NOT ADEQUATE
15) 1 LOG LITE OMITTED ON PLAN
16) PLEASE LEAVE COPY OF LAST INSPECTION RESULTS ON SITE AFTER EACH INSPECTION