Permit: T04CM03587

Parcel: 141016180

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM03587

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/21/2004 FRAMING Approved IVRS - Inspection :*
12/20/2004 FRAMING Partial Approval IVRS - Inspection :*
1) FINISH INT. H.D. BOLTS MASTER BATH LAUNDRY WALL
12/06/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) CLEAN OUT ALL DEBRIS
2) DRY UP H20 ON FLOOR
3) WALK THE JOB, MANY ITEMS MISSING. EXAMPLE: HD'S, FIRE BLOCKING AND MISSING STUD BACKING
4) MOVE PEX 12" FROM LIGHT CANS
5) KITCHEN SINK VENT 1/4" PER FT SLOPE, 6" ABOVE FLOOD RIM DRAINAGE FITTINGS OR RUN AT 45 DEGREE ANGLE=VERTICAL
6) TUB SHOW BLOCK OUT WET
7) LOOSE TUB SURROUND, MISSING BACKING
8) LINE SET OUT OF WALL LINE
9) BETTER PITCH LAUNDRY VENT HORIZONTAL PORTION
11/16/2004 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*