Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM03587
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2004 | FRAMING | Approved | IVRS - Inspection :* | |
12/20/2004 | FRAMING | Partial Approval | IVRS - Inspection :* 1) FINISH INT. H.D. BOLTS MASTER BATH LAUNDRY WALL |
|
12/06/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) CLEAN OUT ALL DEBRIS 2) DRY UP H20 ON FLOOR 3) WALK THE JOB, MANY ITEMS MISSING. EXAMPLE: HD'S, FIRE BLOCKING AND MISSING STUD BACKING 4) MOVE PEX 12" FROM LIGHT CANS 5) KITCHEN SINK VENT 1/4" PER FT SLOPE, 6" ABOVE FLOOD RIM DRAINAGE FITTINGS OR RUN AT 45 DEGREE ANGLE=VERTICAL 6) TUB SHOW BLOCK OUT WET 7) LOOSE TUB SURROUND, MISSING BACKING 8) LINE SET OUT OF WALL LINE 9) BETTER PITCH LAUNDRY VENT HORIZONTAL PORTION |
|
11/16/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |