Permit: T04CM03530

Parcel: 111060550

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/01/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
06/27/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :* 1) CLOTHES WASHER STANDPIPE NOT APPROVED. CLOSET FLANGES INSTALLED OK.
06/10/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) IT IS IMPORTANT TO POST YOUR ADDRESS IN ORDER TO INSURE TIMELY INSPECTIONS
2) ABS DWV THRU ROOF OK. WATER TEST OK
3) PEX OK SUBJECT TO APPROVED PLAN. OK TO COVER ALL AREAS
4) RECALL FOR CLOSET FLANGE INSPECTION
06/03/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :* 1) PROVIDE TEST ON ABS. 2) PLAN CALLS FOR COPPER WATER PIPING. 3) IF PEX IS TO BE APPROVED, IT IS NOT ADVISED TO BUNDLE HOT & COLD TOGETHER DUE TO HEAT TRANSFER. 4) REMEMBER -HORIZ X HORIZ CHANGE OF DIRECTION TO BE A SWEEP 5) NO VENT ON WASHER BOX.