Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 01/07/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RECEPTACLE IN MASTER BEDROOM UNIT #2 SHOWING REVERSE POLARITY 2) GFI RECEPTACLE ON ROOF TO UNIT #2 NOT RESETING |
|
| 11/15/2007 | ELECTRIC - FINAL | Not ready for Inspection | WORK IN PROGRESS | |
| 10/31/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. ROMEX NOT ALLOWED AS A CORD 2. USE APPROVED PLATES FOR WATER HEATER MAKE UP BOX 3. PROVIDE DISCONNECTING MEANS FOR WATER HEATER 4. PANEL SCHEDULE TO BE LEGIBLE 5. BOXES MORE THAN 1/4" 314.20 6. SHEETMETAL SCREWS NOT ALLOWED FOR GROUNDING 7. FILL IN EXCESS GAP AROUND PANEL - 408.2 & 314.21 8. NO FURTHER INSPECTIONS UNTIL VERIFY QUALIFIED ELECTRICAL PERSON |
|
| 09/12/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* ON ROOF 1. PROPERLY IDENTIFY COMPRESSOR DATA PLATES AS TO HEAT STRIPS (IF ANY) ARE INSTALLED - NEC 424.29, 440.4 2. CONDENSATE DRAIN LINE NOT TO BE IN FRONT OF DISCONNECT -- NEC 110.26 3. DINING ROOM 3 WAY LIGHT SWITCH NOT WIRED PROPERLY NOT WORKING 4. INSTALL RANGE ANTI-TIP BRACKET 5. RANGE RECEPTACLE AND CORD TO BE 4 WIRE INSTALL RECEPTACLE COVER, CONNECTOR FOR CORD AND REMOVE RANGE BONDING JUMPER 6. PROVIDE CONNECTOR FOR HOOD CORD 7. SMOKE DETECTORS NOT INTER-CONNECTED 8. BATH GFI NOT TESTING/WIRE WRONG? 9. PROVIDE ARC FAULT PROTECTION FOR ALL BEDROOMS RECEPTACLES, LIGHTS AND SMOKE DETECTORS 10. PANEL DIRECTORY NOT PROPERLY IDENTIFIED 11. USE ONLY SQUARE D HOMELINE BREAKER IN PANEL 12. PANEL NOT GROUNDED - NEUTRAL AND GROUNDS TO BE SEPARATED IN SUB-PANEL 13. INSTALL ALL LIGHT BULBS 14. WATER HEATER TO BE GROUNDED AND HAVE PROPER WIRING METHOD (RACEWAY AND PROPER FITTINGS) WORK TO BE DONE BY QUALIFIED ELECTRICIAN INSPECTION FOR #1 ONLY -- GO THROUGH UNITS |
|
| 07/26/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CALL FOR FINAL WHEN #1 METER IS IN NOTE: USE ONLY SQUARE D BREAKERS IN SUB-PANEL |