Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/15/2007 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 08/11/2006 | ELECTRIC - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELLED PER CONTRACTOR |
|
| 06/07/2006 | ELECTRIC - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) OK TO COVER ELECTRICAL 2) REMOVE BONDING JUMPER IN SUB-PANELS FROM NEUTRAL AND PUT IT ON GROUNDS |
|
| 04/20/2006 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. FEEDERS FOR SUB-PANELS NEED TO BE IN RACEWAY OR PART OF A CABLE WITH OUTER JACKET - NOT OPEN WIRING. 2. GROUNDS AND NEUTRALS TO BE SEPARATED IN SUB-PANELS. 3. KITCHEN COUNTER CKT'S SHOULD ONLY SERVE LOADS ALLOWED AND NO OTHERS. 4. INSTALL RANGE CKT. |