Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM03518
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/21/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :*/ 1) ADD A35 AT GARAGE LEDGER 2) NEED TRUSS REPAIR DETAIL AT NEXT INSP | |
09/15/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NAIL BLOCK OSB RUN PARALLEL WITH TRUSS. NAIL FILL BLACK MARKS ON ROOF DECK 2) X BRACES NOT NAILED AT ENDS 3) NEED A.35 12" ON CENTER REAR GABLE TO WALL 4) MISSED SHEAR AT REAR CONTINUE TO DOOR 5) DAMAGED TRUSS MARKED ON FLOOR 6) NAILS MISSING IN PORCH HANGERS 7) X BRACE END 25' 8) H.D.'S GET 5/8" DIAMETER BOLTS 9) REPLACE DAMAGED OSB AT FRONT 10) A.35 AT FRONT BEDROOM IN CONC. RETRO 3-TOTAL 12) GARAGE TO HOUSE GABLE TRUSS FLAT VERTS. 2 X 4 LOOSE |