Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T04CM03500
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2005 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* 1) GAS PRESSURE TEST IS OK 2) BOND HAS BEEN IN PLACE FOR GAS |
|
| 08/01/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY FOR INSPECTION |
|
| 07/28/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* NOT READY FOR INSPECTION |
|
| 07/27/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE TERMINATION OF WATER HEATER T & P DRAIN 2) VENT FROM WATER HEATER TO HAVE MINIMUM 6" CLEARANCE FROM COMBUSTIBLES. WATER HEATER VENT REQUIRES DBL WALL THRU CEILING SPACE. NO MORE THAN 60 DEGREE OFF SET ON WATER HEATER VENT |
|
| 07/26/2005 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY FOR INSPECTION |
|
| 07/22/2005 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1) INSTALLATION OF ANSUL VALVE IS OK 2) NO PRESSURE TEST AT THIS TIME 3) ALL GAS APPLIANCES TO BE INSTALLED WITH APPROVED GAS VALVES, FLEXES, SAFETY LABELS FOR GAS CLEARANCE CARD. SEE NOTES FROM 5/24/05 INSPECTION |
|
| 07/20/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHALL PROVIDE RIGHT AND LEFT NIPPLES WHEN ANZEL VALVE IS LOCATED ABOVE CEILING TILE |
|
| 05/24/2005 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 1) TEST OK ONLY- WILL NEED TO INSTALL SOLENOID, ALSO NO UNIONS AT SOLENOID WILL NEED TO MAKE LOCATION OF SOLENOID ON CEILING TILE AT TIME OF FINAL |
|
| 12/15/2004 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* |