Permit: T04CM03499

Parcel: 140375720


Addresses:

5921 E CEDARBIRD DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/29/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/24/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :GARAGE EAST WALL SHEER RENAIL PROTRUDES TOO MUCH RENAIL
PORCH STEPS NOT NAILED
FRONT RIDGE SOUTH END 2 LOOSE SHEETS
LOOSE SHEET OVER SOUTH EAST BEDROOM
11/22/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) GARAGE SHEAR EAST WALL TO MANY SHINERS MISSED STUDS
2) ANCHOR BOLTS MISSING NUTS AT FRONT POP-OUTS
3) WIND BRACES REQUIRE TWO NAILS AT ENDS
4) CHECK GABLE TRUSS NAILING
5) NO ACCESS TO ROOF
6) STOPPED INSPECTION, TO MANY ITEMS