Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2005 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) HCS CONNECTION IS OK 3) BACK WATER VALVE INSTALLATION IS OK 4) OK FOR BACKFILL. | |
| 01/24/2005 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY FOR INSPECTION |
|
| 01/20/2005 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BACKWATER VALVE SHALL BE LOCATED BETWEEN TWO WAY C.O. 2) SHALL PROVIDE A 3X2 SAN TEE FOR TRAP ARM @ MOP SINK 2" TRAP ARM SHALL CONTINUE ALL THE WAY TO THE BARREL 3) CANNOT LOCATE A THREADED FITTINGS IN A CONCEALED LOCATION @ SEWER MAIN. 4) SHALL PROVIDE UNIONS ON BACKFLOW PREVENTER 5) APPROVED PLANS DO NOT HAVE PLAN CHECKERS SIGNATURE. |