Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T04CM03493

Parcel: 11704158B


Addresses:

625 N 9TH AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
01/07/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/21/2004 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) ALL SHEAR PANELS OK
2) H2.5 HARDWARE MUST BE INSTALLED PER MANUFACTURERS RECOMMENDATION
3) OK TO STUCCO MESH
12/20/2004 EXT METAL CLIPS/EXT SHEATHING Cancelled CANCELLED BY STEVE 406-36322; CALLED ROB
12/20/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) 2ND TIME I HAVE BEEN HERE, UNABLE TO LOCATE PLANS, CANNOT DO THE INSPECTION WITHOUT THEM
11/24/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :CALLED OWNER, NO PLANS, WILL RECALL FOR FRIDAY
WALKED UPPER ROOF, OK EXCAPT ONE 1/2 SHEET O.S.B. TURNED PARRALLEL WITH ROOF JOISTS BLK EDGES & AT 24", ITS MARKED ON ROOF
CANNOT VERIFY FRAMING WITHOUT PLANS