Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/28/2005 | FRAMING | Approved | IVRS - Inspection :*AP | |
| 01/26/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) EXHAUST FAN AT MASTER BATH 2) OK TO INSULATE |
|
| 01/25/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) SMOKE DETECTOR OUTSIDE BEDROOMS 2) SEAL MECH CHASE 3) SEE NOTES #2 ? INSPECTION DATED 1/21/05 4) REST OF HOUSE OK |
|
| 01/21/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL PROTECT ELECTRIC IN MASTER BEDROOM 2) SUPPORT PLUMBING AT LAUNDRY ROOM 3) OVERSPAN AT LANDING AND KITCHEN 4) ELECTRIC BOX NOT INSTALLED AT STAIRS 5) FIREBLOCKS AT MASTER BEDROOM CLOSET |
|
| 01/20/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE INSPECTION DATED 1/19/05 |
|
| 01/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL MECHANICAL AND B-VENT CHASES 2) PROVIDE SMOKE DETECTOR OUTSIDE BEDROOM 3) OVERSPANS AT FRONT BEDROOM 4) FIREBLOCKS AT MASTER CLOSET 5) NAIL PROTECT ELECTRIC AT MASTER BEDROOM 6) SPT PLUMBING AT LAUNDRY 7) HEADERS UNDER STAIRS NOT SITTING ON KING 8) MASTER BEDROOM NOT PER PLAN MISSING WINDOW AND CLOSET ADDED ? 9) PROVIDE REVISION OR BUILD PER PLAN |