Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 02/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEWER LINE MUST BE 12" BELOW GRADE OR USE METAL PIPE 2) WEST SIDE OF ADDITION IS 2 FEET FROM PROPERTY LINE NO OPENINGS ALLOWED WITHIN 3 FEET OF PROPERTY LINE 3) PROVIDE CITY APPROVED DETAIL FOR FIRE RATING COMBUSTIBLE MATERIAL WITHIN 3 FEET OF PROPERTY LINE 4) HOLDOWNS MUST BE ATTACHED TO FULL LENGTH DBL STUDS AND ALL HOLES FILLED WITH NAILS 5) PLAN CALLS FOR 3 1/8" X 9" GLB AT RIDGE. DBL 2 X 12 USED. BUILD TO PLAN OR REVISE PLAN TO AS BUILT 6) GLB REQUIRES 4 X 4 POSTS NOT INSTALLED 7) W/C AND SHOWER NOT PROPERLY VENTED 8) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF FRAME SURFACE 9) ROOF NAIL OK BUT GLB SUPPORT NOT PER PLAN |