Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM03453
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
12/09/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/3050-NOT REQUIRED. NO GAS TO BUILDING | |
12/06/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)READ ALL NOTES FROM 12/3/04 INSPECTION ON BOTH HOUSE & LOFT AND MAKE CORRECTION. NOTES PORTAIN TO BOTH UNITS |
|
12/03/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) TEST ALL WASTE AND VENT PIPING WITH AIR OR WATER THRU ROOF 2) SUPPORT SECURE WASTE AND VENT PIPING EVERY 4' ON HORIZONTAL 3) PROVIDE MINIMUM 1/4" PER FOOT FALL ON WASTE PIPING 4) 30 PSI AIR TEST FROM METER TO STOVE AND DRYER (ONLY) OK 5) SECURE GAS PIPING AT DRYER LOCATION |