Permit: T04CM03431

Parcel: 116040220

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/17/2005 FRAMING Approved IVRS - Inspection :*
08/11/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL DBL STUD UNDER GARAGE GIRDER AT BEARING
2) STRAP GARAGE BEARING WALL (N.W. CORNER) INTERSECTION TO MIKEY BLOCK
3) JACUZZI TUB PLUMBING INCOMPLETE
4) MUST INSTALL ADDITIONAL VENT GARAGE TO ALL WITHIN 12" OF CEILING TO EXTERIOR
5) TRUSS BLOCKING NOT DONE
6) PLAN SHOWS SCISSOR TRUSSES CENTER OF HOUSE
08/04/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
GAS METER AND ELEC METER LOCATION NOT PER PLAN
PLAN SHOWS FURNACE IN GARAGE
PLAN CALLS FOR SCISSOR TRUSSES CENTER OF HOUSE
TRUSS BLOCKING MISSING TOP & BOTTOM CHORDS 8' SPACING
KITCHEN SINK LOCATION NOT PER PLAN ALSO DISHWASHER, RANGE, ETC
ALL DWV PIPING TEST TO GO THRU ROOF
WHAT IS PLB PIPING IN FLOOR W/ CAP FOR?
INSTALL TUB AND CONNECT PLB
INSTALL NUTS ON ALL THREAD HOLDING MAIN PAVEL TO WALL AND CUT OFF EXCESS
INSTALL BANG PLATES PLB WITHIN 1 1/2 STUD FACE
INSTALL BANG PLATES ELEC WITHIN 1 1/4" STUD FACE
CANNOT LOCATE 22"X30" ATTIC ACCESS HOLE
SECURE ELEC SUBPANEL TO WALL
GROUND ALL METAL ELEC BOXES IN FOAM WALLS
STRAP GARAGE BEARING WALL TO TO PLATE ON TOP OF MIKEY BLK WALL
INST DBL STUDS UNDER GARAGE GIRDER TRUSS @ BEARING
MAINTAIN MIN 1" CLEARANCE H20 HEATER FLUE PIPE TO COMBUSTIBLES
SEPARATE NEUTRALS AND GROUNDS ELEC PANEL AND GRND BX
PUT 2" SOIL PIPE VENT? BACK INTO WALL
STOPPED INSP