Permit: T04CM03431

Parcel: 116040220

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/19/2005 ROOF NAILING Approved IVRS - Inspection :*
07/15/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED APPROVED TRUSS DRAWINGS
2) CROSS BRACE TRUSSES IN CENTER (OVER 25' OF MAXIMUM RUN)
3) INSTALL PLATE BOLTS WITH 12" EACH END OF PLATES ON TOP OF MILKEY BLOCKWALLS
4) TRUSS END WALL NOT FRAMED PER DETAIL "F"
5) BOLTS SPACING NOT PER PLAN
6) NEED LADDER TO ACCESS ROOF
7) STOPPED INSPECTION
07/13/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO SUBMIT ASBUILT DETAILS RE: REBAR PER ? PREVIOUS PAPERWORK
2) CALL IN 1020-PRE GROUT
3) ONCE THAT IS RESOLVED YOU CAN CALLL IN 1030-ROOF NAIL