Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM03428
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/30/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/24/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 09/21/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) OK TO COVER ALL BUT AREA, THAT NEEDS A NEW BEAM AT DINNING ROOM TO KITCHEN OPENING NEED DBL 2 X 8 WITH A PLYWOOD FLITCH PLATE 2) NEED A GAS TEST 3) AT CARPORT USE 3/8-5/16 LAGS INTO EXISTING STUDS AT LEDGER TO WALL, SISTER 2 X 8 TO EXISTING 2 X 6 RAFTERS STAGGER NAIL 16" ON CENTER, ADD ADDITIONAL 2 X AT POST BEAM BEARING 4 2.5 BOTH ENDS OF RAFTER 4) 13'-6" SPAN=2 X 8 |