Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM03404
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/09/2004 | FRAMING | Approved | IVRS - Inspection :* | |
11/08/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) FIREBLOCK MISSING KITCHEN SOFFIT 2) PROVIDE REVISION 5/SD-3 OR BUILT TO PLAN |
|
11/05/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 5/D3 NOT COMPLIED WITH |
|
11/04/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 5/D3 NOT COMPLIED WITH 2) GARAGE MISSING TRUSS BRACES AND B/R 2 3) 2 X BLOCKING NOT INSTALLED PER 1/D3 4) NAIL FLUSH TO TOP PLATE 5) PLUMBING CANNOT BE IN ATTIC ACCESS 6) FIREBLOCKING MISSING KITCHEN 7) SHEAR WALL IN GARAGE NOT NAILED |