Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/13/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/10/2004 | FRAMING | Partial Approval | IVRS - Inspection :* 1) 2" DIRY ARM NOT ALLOED ON LAV 2) WATER LINES OK 3) RETEST DWV'S 4) SEE #4 AND #8 INSPECTION DATED 12/08/04 5) FIRE BLOCK F/P AREA |
|
| 12/08/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) KING STUD MISSING AT SGD OPENING 2) PROVIDE 12" CLEARANCE FROM CAN LIGHTS FOR WATER LINES 3) BLOWN FIRE BLOCK AT MASTER BATH 4) CLIP 2 X 6 STUD AT SHEAR TRANSFER MASTER TOILET 5) OVER SPAN AT BEDROOM 2 6) REPAIR ARMA FLEX IN ATTIC SPACE 7) NOT ALLOWED TO USE PLUMBERS TAPE TO SUPPORT AB'S 8) 1 1/2 DIRTY ARM EXCEEDS 42" AT HALL BATH 9) REMOVE SCREEN FROM DRYER VENT 10) STOPPED INSPECTION |
|
| 12/03/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ENTRY TOWER FRAMING NOT PER PLAN 2) COLUMN TRUSS MUST BEAR ON DBL TOP PLATES 3) NAIL PROTECT ELECTRIC WITHIN 1 1/4' FROM EDGE OF STUD 4) FIRE BLOCK MISSING AT KITCHEN WALL 5) NO TEST ON DWV'S 6) STOPPED INSPECTION |