Permit: T04CM03389

Parcel: 140050360


Addresses:

3568 E FELIX BL


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM03389

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/17/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*/ 1) RE-INSPECT
10/14/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/ 1) NOT READY PER SUPER
10/13/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SW 9 REQUIRES 2" ON CENTER AND BLOCK SEAMS 2) PORCH MISSING LSL 17/SD4 3) HOLDOWN ON SW 11 WRONG LOCATION NORTH END 4) SOUTH SHEAR WALL TOO SMALL
10/12/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 2 NAILS REQUIRED AT TOP AND BOTTOM METAL BRACE 2) DRIVE NAIL FLUSH AT HOLDOWN REAR S.G.D. 3) NO ACCESS TO ROOF 4) CHECK ALL DETAILS FOR REQURIED 8D'S NAILING
10/08/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/COMPLETE STAIRS & PORCH