Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM03389
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/17/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :*/ 1) RE-INSPECT | |
10/14/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) NOT READY PER SUPER | |
10/13/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SW 9 REQUIRES 2" ON CENTER AND BLOCK SEAMS 2) PORCH MISSING LSL 17/SD4 3) HOLDOWN ON SW 11 WRONG LOCATION NORTH END 4) SOUTH SHEAR WALL TOO SMALL |
|
10/12/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) 2 NAILS REQUIRED AT TOP AND BOTTOM METAL BRACE 2) DRIVE NAIL FLUSH AT HOLDOWN REAR S.G.D. 3) NO ACCESS TO ROOF 4) CHECK ALL DETAILS FOR REQURIED 8D'S NAILING |
|
10/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/COMPLETE STAIRS & PORCH |