Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM03387
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :*/ 1) PROVIDE ENGINEERING REPAIR AT S.W. CORNER 2) CONCRETE BROKEN IN INTER. | |
10/14/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :*/ 1) NEED REPAIR, AND SPECIAL INSP. FOR S/W CORNER H.D. 14 BOLT J HOOK CONTRETE BROKEN | |
10/13/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO PRIOR INSPECTION REPORT FOR 10/12/04 ON SITE 2) 26/S1.2 NOT COMPLIED WITH 3) SHEARWALL #9 NOT NAILED PER PLAN 4) SHEARWALL 5 NOT NAILED 5) GIRDER TRUSS REQUIRES DBL 2 X 6 POST TO ? 6) NW HOLDOWN BROKEN 7) PROVIDE DETAILS FOR ALL POST/BEAM CONNECTIONS 8) SW BROKEN ABOVE GLB IN GARAGE AND HD ? 8 NOT IN |
|
10/12/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) DRIVE NAIL HEADS FLUSH AT SHEARWALL 2) PROTECT PLUMBING/BANG PLATES MISSING 3) COMPLY WITH S1.1 (11) AND S1.2 (26) 4) ALL REQUIRED EDGE NAILING SHALL BE #8 AT 6" ON CENTER |
|
10/11/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |