Permit: T04CM03385

Parcel: 12203075C


Addresses:

2225 N BELL AV #01

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
01/18/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
01/17/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*LIGHTING TO BE CONNECTED TO ARC FAULT SMOKE DETECTORS TO BE ON ARC FAULT WHEN INSIDE BEDROOM
01/12/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) WEATHER PROOF RECPTACLE COVER TO BE WHEATHER PROOF WHETHER OR NOT PLUGGED IN TO 406.8
2) AN APPROVED EXTENDER RING IS NEEDED AT BOXES NOT FLUSH IN COMBUSTIBLES
3) BEDROOMS TO HAVE ARC FAULT PROTECTION 210.12
4) FOR ROOF: ONLY ONE CONDUCTOR PER TERMINATION
5) NEUTRALS NOT TO BE CONNECTED TO GROUNDS
6) PLEAS SUPPORT MAINTENANCE RECEPTACLE