Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/20/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/19/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) NO GAS BOND 2) #2 SHEAR BLOCK MISSING AT GAS LINE 3) SHEAR BLOCKING PANEL DAMAGED AT DINING ROOM 4) NAIL PROTECT PLUMBING WITHIN 1 1/2" OF STUD SURFACE 5) DBL TOP PLATES NOTCHED GREATER THAN 40 PERCENT-INSTALL FHA STRAPS AT CONDENSATE LINES 6) ANCHOR BOLT MISSING NORTH WALL 7) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 8) LAV TRAP ARM MUST BE SAME SIZE AS TRAP NOT 3" MAX 1 1/2" 9) LEAK AT CLEANOUT 10) AC WIRES NOT OUTSIDE 11) STOPPED INSPECTION, TOO MANY ITEMS 11) LATH WIRE MISSING MANY PLACES |