Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T04CM03361
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/05/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
01/03/2005 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :*/1)NEED SCREEN, ON TEE TOPS, EXCEPT DRYER VENT 2)SOFT SPOT ON PARAPET STUCCO 3)NEED MIN 1' 0" FROM METAL PAN TO BOTTON OF VENT CAP F/PLACE 4)FURNACE VENT PIPE FOR EXHAUST TO GO INSIDE FLUE CAP. NOT TO TERMINATE INSIDE COMBUSTION AIR SOURCE 5)CLAMP COOK TOP FLEX TO CABINET OUT OF WAY 6)ADD NAIL TO POST BASE REAR PORCH. |