Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2005 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/23/2004 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 12/22/2004 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)FRONT PANCAKE BOX NOT GROUNDED 2)PROVIDE PROPER SLOPE FOR B-VENT 3)CONTINUE BLOCKS AT 4' PER 2SD2, FOR 8 FASTENERS FOR SHEET ROCK NAILING. 4)SECURE ELEC WIRE WITHIN 8" FROM BOX 5)FIRE BLOCKS MISSING AT BED ROOM ABOVE GARAGE 6)PROVIDE 6" CLEARANCE FOR WATER LINKS AT B-VENT CHASE 7)SECURE GAS LINE IN ATTIC 8)INSULATE BEHIND TUBS |