Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/12/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/05/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) MOVE ELECTRIC WIRE AWAY FROM GUSSET PLATES AT KITCHEN 2) 8' BRACES CUT UPSTAIRS 3) OK TO INSULATE |
|
| 12/23/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PEX REQUIRES 6" CLEARANCE TO W/H "B" VENT 2) PROVIDE H2.5 CLIPS TO BOTH ENDS OF BLOCKS AT 2/SD2 OR PROVIDE ENGINEERS CLEARIFICATION OF ONLY ONE INSTALLED HWNE TWO TRUSSES INVOLVED 3) STAIRS HAVE GREATER THAN 3/8" DIFFERENCE IN RISE TOP AND BOTTOM OF STAIR AND RISE MORE THAN 7 3/4 |
|
| 12/22/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |