Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/05/2005 | FRAMING | Approved | IVRS - Inspection :* | |
07/01/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) LATHE NOT COMPLETE 2) NEXT INSPECTION SUBJECT TO REINSPECTION FEE |
|
06/29/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
06/28/2005 | FRAMING | Denied | 1. NO LATHE INSTALLED 2. FIRE BLOCK MISSING AT DRYER VENT 3. EXHAUST VENT MISSING AT LAUNDRY 4. FIRE BLOCK MISSING AT ELEC. 5. LEDGER CLIPS AT PATIO MISSING NAILS 6. FIRE BLOCKS AT LAUNDRY AND CLOSER TO LOW 7. SECURE WIRES WITHIN 8" FROM 2 GANGBOX AT BATHROOM 8. GRCA OUTLET MUST BE WITHIN 36" FROM EDGE OF LAV IN BATHROOM |
|
06/27/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
06/23/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ELECTRICAL NOT COMPLETE 2) WATER LINES NOT COMPLETE AND NEED 12" CLEARANCE FROM CAN LIGHTS 3) NAIL PROTECT ELECTRIC WITHIN 1 1/4 FROM EDGE ON STUD PLUMBING WITHIN 1 1/2 FROM EDGE OF STUD 4) 1/4" OF ROMEX SHEATHING INTO ELECTRIC BOX 5) EXTEND P-TRAP ABOVE FINISHED FLOOR 6) SHOWER DIVERTER NOT INSTALLED 7) HOUSE NOT LATHED 8) DRYER VENT FLEX NOT ALLOWED AND NAIL PROTECT 10) STOPPED INSPECTION |
|
06/22/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) COMPLETE ALL TRADES AND RECALL |
|
06/21/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NO LATH ON STRUCTURE |
|
06/20/2005 | FRAMING | Cancelled | CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR F. GREER |