Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2005 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) REFER TO COMPLAINTS |
|
| 03/15/2005 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1) HOUSE AND SUB-PANEL APPROVED 2) NEED PERMIT FOR PANEL UPGRADE 3) T/P LINE THRU ROOF REQUIRES 90 ON ROOF DIRECT FLOW DOWN AND REQUIRES DRAIN VALVE IN WATER HEATER CLOSET 4) REMOVE TAPE CONNECTION CONNECTOR PIPE AND B-VENT OF WATER HEATER 5) RE-SHEETROCK CEILING OF HEATER CLOSET 6) EXPOSED ABS S.E. CORNER MUST BE COVERED OR CHANGED TO STEEL PIPE 7) DRAIN CANNOT BE REDUCED FROM 2" TO 1 1/2" 8) ANGLED PLUG ON FURNACE DOES NOT ALLOW IT TO BE PLUGGED IN |
|
| 01/07/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HALL BATH GFI HAS OPEN GROUND 2) OPEN GROUND BEDROOM RECEPTACLE 3) 3 KITCHEN RECEPTACLES INOPERABLE 4) NEED RECEPTACLE ON END OF PENENSULA AND IN ISLAND 5) ON BATHROOM MUST BE OPTIONAL 6) T/P LINE MUST BE 3/4" WITH DRAIN VALVE 7) B-VENT CANNOT BE SEALED |
|
| 01/06/2005 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 07/21/2004 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* |