Permit: T04CM03344

Parcel: 133300360


Addresses:

8802 E SHILOH PL

Inspection Status: Not ready for Inspection

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
08/18/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1) REFER TO COMPLAINTS
03/15/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) HOUSE AND SUB-PANEL APPROVED
2) NEED PERMIT FOR PANEL UPGRADE
3) T/P LINE THRU ROOF REQUIRES 90 ON ROOF DIRECT FLOW DOWN AND REQUIRES DRAIN VALVE IN WATER HEATER CLOSET
4) REMOVE TAPE CONNECTION CONNECTOR PIPE AND B-VENT OF WATER HEATER
5) RE-SHEETROCK CEILING OF HEATER CLOSET
6) EXPOSED ABS S.E. CORNER MUST BE COVERED OR CHANGED TO STEEL PIPE
7) DRAIN CANNOT BE REDUCED FROM 2" TO 1 1/2"
8) ANGLED PLUG ON FURNACE DOES NOT ALLOW IT TO BE PLUGGED IN
01/07/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HALL BATH GFI HAS OPEN GROUND
2) OPEN GROUND BEDROOM RECEPTACLE
3) 3 KITCHEN RECEPTACLES INOPERABLE
4) NEED RECEPTACLE ON END OF PENENSULA AND IN ISLAND
5) ON BATHROOM MUST BE OPTIONAL
6) T/P LINE MUST BE 3/4" WITH DRAIN VALVE
7) B-VENT CANNOT BE SEALED
01/06/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
07/21/2004 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*