Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/18/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/17/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO POST TENSION TAG 2) PAINT IRRIGATION PVC 3) FINISH GRADE AROUND HOUSE NOT PER CODE 4) B1 TRUSS REPAIR NOT APPROVED BY CITY OF TUCSON 5) STOPPED INSPECTION |
|
| 02/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLAN OR PERMIT 2) EXPOSE REPAIR ON BOTH SIDES |
|
| 01/26/2005 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection No plan/permit on site |
|
| 01/12/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NO REPAIR DONE AT KITCHEN WALL DBL TOP PLATE 2) NO CITY OF TUCSON APPROVED REPAIRS FOR KITCHEN WALL TRIPPLE GIRDER OR B1 TRUSS |
|
| 01/11/2005 | FRAMING | Partial Approval | IVRS - Inspection :*/1)MECHANICAL CHASE NOT FIRE BLOCKED 2)FRAMING PARTIAL PENDING CITY OF TUCSON APPROVAL FOR TRIPPLE GIRDER, B1 TRUSS AND KITCHEN WALL REPAIR DBL TOP PLATE | |
| 01/07/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) DWV'S WATER LINES OK 2) SEAL ALL PENETRATIONS FROM 1S T TO 2ND FLOOR AND INTO ATTIC SPACE 2) WATER LINE AT DINING AREA BELOW CEILING LINE NOT SECURED 3) NAIL PROTECT T & P LINE 4) FIREBLOCK MECH CHASE INTO ATTIC 5) PARTIAL FRAMING PENDING CITY OF TUCSON STAMP OF APPROVAL, OK TO INSULATE, LEAVE ACCESS TO ITEMS NOT INSPECTED |
|
| 01/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER LEAKS AT MANIFOLDS 2) PROVIDE ENGINEERING FOR SHEAR TRANSFER WALL AT KITCHEN 3) SEAL ALL PENETRATIONS 4) WATER LINE BELOW CEILING NOT SECURED AT DINING AREA 5) PROVIDE GIRDER AND TRUSS REPAIR. SEE LAST INSPECTION |
|
| 01/05/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER LEAK AT LAUNDRY ROOM CEILING 2) PROVIDE 3 PLY GIRDER REPAIR 3) B1 TRUSS BOTTOM CHORD CRACKED, REQUIRES ENGINEER APPROVAL 4) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR AND TO ATTIC SPACE 5) PROVIDE ENGINEERING FOR DBL TOP PLATE SHEAR TRANSFER WALL AT KITCHEN |