Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/16/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ELECTRICAL IN LAUNDRY NOT COMPLETE 2) PROVIDE PROOF OF APPROVED CMU WALL INSPECTION 3) OK TO INSULATE |
|
| 03/10/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) SANITARY T FITTING CANNOT BE USED AS A HORIZONTAL DRAIN FITTING AT KITCHEN SINK 2) KITCHEN SINK DRAIN VENT MUST BE CONNECTED TO DRAIN ABOVE THE CENTER LINE OF THE DRAIN 3) RANGE ELECTRIC CABLE MUST TERMINATE IN AN APPROVED BOX 4) NO DWV SEWER WATER TEST 5) BEARING STUD NOTCHED MORE THAN 25 PERCENT BY RANGE HOOD 6) EXHAUST FAN DUCT NOT INSTALLED 7) NAIL PROTECT PLUMBING NORTH BATH 8) STOPPED INSPECTION INTERMEDIATES |