Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) STUB TRUSSES REQUIRE SHEATING. 2) CANNOT APPROVE UNTIL MASONRY WALLS ARE APPROVED BY CITY OF TUCSON. 3) ITEM 5 OF 10 NOT COMPLIED WITH. OK TO DRY IN ROOF. | |
| 10/06/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PROVIDE PROOF OF MASONRY WALL INSPECTION BY CITY OF TUCSON INSPECTION 2) OSB ROOF SHEATHING MUST SPAN 3 TRUSSES (TWO BAD) 4 UNDERSIZED PANELS INSTALLED 3) STUB TRUSSES REQUIRE 1/2" C.D.X. B/5.4 4) 5/3.4 AND 5/3.4 NOT COMPLIED WITH 5) 4 X 10 BEAM NOT IN SADDLE PER 2/5.4 |
|
| 09/13/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :*/ 1) SIDING ON ALL UNITS APPROVED BY HEIGHT OF 8' |