Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/20/2004 | PLUMBING - ROUGH, SOIL | Approved | ||
| 12/01/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/1)SOIL WATER TEST IS OK. 2)THIS INSPECTION IS FOR UNDER SLAB R.W.L. SYSTEM ONLY. 3)OK TO BACKFILL TRENCH. | |
| 11/30/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 11/29/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 11/24/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/1)PVC SCH. 40 PIPE APPROVED FOR WATER ONLY HAS BEEN ACCEPTED BY DAVE MANN IN LIEU OF DWV ON 11/23/04. SEE ATTACHED LETTER FROM ARCHITECH. 2)OK TO BACKFILL TRENCH LEAVING ALL UNDERGROUND FITTINGS EXPOSED | |
| 11/23/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SYSTEM NOT TO CODE |
|
| 11/05/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)SHALL USE APPROVED MATERIALS FOR DRAINAGE AND DRAINAGE FITTINGS AND AS PER SPECS ON APPROVED PLANS 2)SHALL PROVIDE WATER ON AIR TEST ON SYSTEM @ TIME OF INSPECTION 3)SHALL VERIFY PLUMBING CONTRACTOR LICENSE @ TIME OF NEXT INSPECTION 4) DO NOT COVER |