Permit: T04CM03318

Parcel: 140374920


Addresses:

6097 E GULL CT

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/15/2004 FRAMING Approved IVRS - Inspection :*
12/09/2004 FRAMING Denied IVRS - Inspection :
1) A reinspection fee has been assessed for this inspection. Multiple inspection
2) See inspection dated 12/01/04, 12/01/04 and 12/06/04
12/06/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE INSPECTIONS DATED 12/01/04 AND 12/02/04 AND COMPLY
2) NEXT FAILURE WILL RESULT IN A REFEE
12/02/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NAIL PROTECT WATER HEATER LINES
2) INTERIOR HOLDOWNS MISSING
12/01/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 2 EXTERIOR PANCAKE BOXES NOT PROPERLY GROUNDED
2) INTERIOR HOLDOWNS MISSING AT GARAGE WALL
3) PLUMBING AT WATER HEATER AREA OUT OF WALL
4) FIRE BLOCK MECH CHASE
5) INSUALTE BEHIND TUB
6) REPLACE 2 X 6 EXTERIOR STUD AT HALL BATH
7) ABS AT POWDER ROOM NAILS PENETRATED
8) BOND FROM PANEL TO GAS LINE NOT INSTALLED
9) RETEST DWV'S WATER LINES