Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/02/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 12/01/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*NAIL PROTECT WATER LINES AT WATER HEATER-WATER LINES MUST BE 6" AWAY FROM B. VENT - BLOCK MECH IN KITCHEN - WATER LINES REQUIRE 12" CLEARANCE FROM CAN LIGHTS - PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT B-VENTS - T & P DRAIN LINE MUST DRAIN AWAY FROM HOUSE - STOPPED INSPECTION |
|
| 11/29/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |