Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM03296
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)THIS INSPECTION IS FOR ALL FITTINGS UNDERSLAB THAT WOULD NOT HOLD WATER TEST. 3)OK TO BACKFILL TRENCH | |
12/13/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 1) WATER PIPING TO HAVE HOT & COLD SEPARATION ( KITCHEN) 2) 1ST FLOOR VENT THRU ROOF NEEDS WATER TEST 2ND FLOOR WASTE & VENT WATER TEST THRU ROOF | |
12/09/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
12/06/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1_PLEASE READ ALL NOTES FROM 12/3/04 INSPECTION ON BOTH HOUSE & LOFT. NOTES PERTAIN TO BOTH UNITS. 2)WATER OR AIR TEST THRU ROOF ALL WASTE & VENT PIPING. 3)PROVIDE SEPERATION OF HOT & COLD H2O TUBING. |
|
12/03/2004 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SUPPORT AND SECURE WASTE VENT PIPING PROPERLY 2) SANTEE -X-P-TRAP REQUIRES 2 PIPE DIAMETER TO PRESENT S-TRAP |