Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM03249
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2005 | FRAMING | Approved | IVRS - Inspection :* | |
01/31/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
01/21/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) BANG PLATE ALL PIPES AND WIRES 2) ANCHOR BOLTS REQUIRED 12" FROM EACH END OF PLATE SPLICE AND 6' ON CENTER THERE AFTER 3) CONNECT EXHAUST FAN CENTER BATH 4) NEED DRAIN WASTE AND VENT SYSTEM H20 TESTED 5) 50 PSI ON H20 LINES OR NORMAL WORKING PRESSURE, H20 ON 6) NEED 110 OUTLET FOR RANGE 7) BLOCK ALL MECHANICAL DUCTS 8) ALL CLOSET LIGHTS, COMPLY WITH CODE 12" ARC. FROM SELF, 6" ARC. FOR RECESSED, OR FLOURESCENT LIGHT 9) SECURE ALL INTERIOR BOTTOM PLATES 1) CHECK MANUFACTURERS BOOK FOR HOLE, SIZE AND DISTANCE IN TJI ? |
|
11/30/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) OK TO INSTALL STUCCO MESH 2) FRAMING TO BE APPROVED AFTER ALL OTHER TRADES ARE COMPLETED |