Permit: T04CM03240

Parcel: 110030720

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/11/2005 FRAMING Approved IVRS - Inspection :*
01/07/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TO BE APPROVED WHEN ALL TRADES ARE COMPLETE
2) NO WATER IN SYSTEM
3) REFEE-3RD TIME NO WATER IN SYSTEM
01/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TO BE APPROVED WHEN ALL OTHER TRADES ARE COMPLETED
2) NAIL PROTECT ROMEX AT TOP PLATES MICROWAVE BOX
3) NO WATER IN SYSTEMS
01/05/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BLOCK REGISTERS 3 SIDES FRONT BATH
2) FRAMING TO BE APPROVED WHEN ALL OTHER TRADES ARE COMPLETED
3) NAIL PROTECT MICROWAVE BOX AT TOP PLATE AND LIVING ROOM NORTH WINDOW AT SILL
4) NO WATER IN SYSTEMS NOT READY
5) PROVIDE TRUSS CALC'S