Permit: T04CM03239

Parcel: 110030720

Inspection Status: Not ready for Inspection

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/27/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
09/27/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/24/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/ 1) HIP JACKS AT FRONT WINDOW, BEARING PT BEYOND DBL TOP PLATE 2) TWO NAILS REQUIRED IN EACH WIND BRACE 3) SMALL CURTAIN WALL IN FRONT OF FRONT WINDOW END NOT NAILED 4) NEED TRUSS DRAWINGS, 3 PT GIRDER NOT SHIELDED 5) UNBLOCKED EDGES AT ROOF DECK 6) DBL STUD UNDER ALL BEARING PTS INCLUDE 3 PT BEARING 7) ADD STUD BACKING REAR BATH/CLOSET #1 SHEARWALL
09/23/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*/ 1) STUDS NOT CLIPPED 2) HOLDOWNS NOT NAILED 3) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 4) HOUSE NOT READY