Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 09/27/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/24/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) HIP JACKS AT FRONT WINDOW, BEARING PT BEYOND DBL TOP PLATE 2) TWO NAILS REQUIRED IN EACH WIND BRACE 3) SMALL CURTAIN WALL IN FRONT OF FRONT WINDOW END NOT NAILED 4) NEED TRUSS DRAWINGS, 3 PT GIRDER NOT SHIELDED 5) UNBLOCKED EDGES AT ROOF DECK 6) DBL STUD UNDER ALL BEARING PTS INCLUDE 3 PT BEARING 7) ADD STUD BACKING REAR BATH/CLOSET #1 SHEARWALL | |
| 09/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) STUDS NOT CLIPPED 2) HOLDOWNS NOT NAILED 3) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 4) HOUSE NOT READY |