Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM03219
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK 2) P.O.C. OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK 3) OK TO BACKFILL TRENCH | |
| 08/05/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK 2) P.O.C. OF NEW BLDG DRAINS IS OK 3) OK TO BACKFILL TRENCH 4) OVERHEAD WATER DISTRIBUTION AIR PRESSURE TEST IN PLBG WALLS ONLY ARE OK 5) NOTE: TRAP ARM FOR MOP SINK EXCEEDS MAXIMUM DISTANCE AND THIS TRAP REQUIRES A VENT |