Permit: T04CM03212

Parcel: 120074610

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
10/06/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/30/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection READ ALL NOTES FROM 9/28/04 INSPECTION AND COMPLY WITH THEM
09/29/2004 PLUMBING - ROUGH, SOIL Denied 1) THERE IS NO BRIDGING ALLOWED. SHALL SHADE ENTIRE TRENCH TO TOP OF PIPE. 2) CANNOT LOCATE A THREADED FITTINGS IN A CONCEALED LOCATION SHALL USE ?YE WITH PERM CAP. 3) TUBS ON ONE SIDE DO NOT MEET. THE MIN TRAP ARM DISTANCE. 4) DO NOT COVER.