Inspection History Details
Permit: T04CM03205
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/02/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/31/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) FRONT AND BACK DORMERS NOT NAILED OFF 2) NEED DIAGONAL BRACING ON EAST SIDE 3) NORTH GABLE TRUSS NOT STRAPPED DOWN 4) CUT VIEW HOLES IN COLUMSN 5) RED HEADS NEEDED IN SOUTH COLUMNS 6) STUD CLIPS NEEDED EAST SIDE 7) SOUTH 2ND FLOOR SHEAR NOT NAILED |