Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/18/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 02/17/2005 | FRAMING | Cancelled | CANCELLED PER LOURDES OF K.B. HOMES | |
| 02/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLAN OR PERMIT 2) EXPOSE REPAIR BOTH SIDES |
|
| 02/14/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO ACCESS |
|
| 01/25/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) SEE INSPECTION DATED 1/12/05 |
|
| 01/12/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED CITY OF TUCSON APPROVED REPAIRS FOR KITCHEN WALL AND TRIPPLE GIRDER |
|
| 01/11/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 01/10/2005 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection. Mechanical chase not fire blocked Double top plate at kitchen not repaired and paperwork not approved by city of Tucson Need paperwork on triple girder Mechanical intermediate will be changed from approved to denied |
|
| 01/07/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 01/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS INCOMPLETE CANNOT LOCATE SHEET SD/2 IN PLANS 2) STOPPED INSPECTION |
|
| 12/30/2004 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio |
|
| 12/29/2004 | FRAMING | Denied | IVRS - Inspection : There is no plan or job inspection card on site.| 925* |
|
| 12/28/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO CHANGE FROM 12/16/04 INSPECTION ITEMS 1, 2 AND 3 NOT COMPLIED WITH STOPPED INSPECTION 2) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE |
|
| 12/22/2004 | FRAMING | Cancelled | IVRS - Ri canceled | |
| 12/16/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) FRONT DOOR PLATES LOOSE, CRACKED, NOT SECURE 2) LOW GAS TEST 7 POUNDS 3) FIREPLACE NOT INSTALLED 4) BACK PITCH 2ND FLOOR TOILET VENT (AT ROLLED UP WYE FITTING) 5) 1ST FLOOR LAV VERT DRAIN OUT OF WALL 6) 8D NAIL HOLE IN WASHER VERTICAL DRAIN AT BOTTOM PLATE HT. NO H20 TEST ON DWV 7) HOW MUCH BEARING IS REQUIRED AT FLOOR TRUSSES 5 1/8 GLU LAM ACROSS KITCHEN LEAVE TRUSS DRAWINGS 8) 12" PEX TO LIGHT CAN AT 1ST FLOOR ACTIVITY ROOM 9) RETRO STHD 16 AT GARAGE NOT NAILED GET EPOXY INSPECTION ON BOLT 10) BACKING AT 2ND FLOOR TUB SIDES 11) RETRO FIT STHD16 AT GARAGE NOT NAILED 12) BACKING AT 2ND FLOOR TUB 13) ? HANGER GET 16D COMMON NAIL 14) BRING BEARING PTS. FOR GIRDER TRUSS ROOF DOWN TO BOTTOM PLATE IN GARAGE/BETWEEN FLOORS, 4-2X4'S |
|
| 12/13/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH INCOMPLETE 2) 2ND REJECTION 3) REFEE DUE 4) STOPPED INSPECTION |
|
| 12/06/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |