Permit: T04CM03203

Parcel: 140375710


Addresses:

5913 E CEDARBIRD DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/18/2005 FRAMING Approved IVRS - Inspection :*
02/17/2005 FRAMING Cancelled CANCELLED PER LOURDES OF K.B. HOMES
02/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLAN OR PERMIT
2) EXPOSE REPAIR BOTH SIDES
02/14/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ACCESS
01/25/2005 FRAMING Partial Approval IVRS - Inspection :*
1) SEE INSPECTION DATED 1/12/05
01/12/2005 FRAMING Partial Approval IVRS - Inspection :*
1) NEED CITY OF TUCSON APPROVED REPAIRS FOR KITCHEN WALL AND TRIPPLE GIRDER
01/11/2005 FRAMING Partial Approval IVRS - Inspection :*
01/10/2005 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection.
Mechanical chase not fire blocked
Double top plate at kitchen not repaired and paperwork not approved by city of Tucson
Need paperwork on triple girder
Mechanical intermediate will be changed from approved to denied
01/07/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
01/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS INCOMPLETE CANNOT LOCATE SHEET SD/2 IN PLANS
2) STOPPED INSPECTION
12/30/2004 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
12/29/2004 FRAMING Denied IVRS - Inspection :
There is no plan or job inspection card on site.| 925*
12/28/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO CHANGE FROM 12/16/04 INSPECTION ITEMS 1, 2 AND 3 NOT COMPLIED WITH STOPPED INSPECTION
2) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE
12/22/2004 FRAMING Cancelled IVRS - Ri canceled
12/16/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
1) FRONT DOOR PLATES LOOSE, CRACKED, NOT SECURE
2) LOW GAS TEST 7 POUNDS
3) FIREPLACE NOT INSTALLED
4) BACK PITCH 2ND FLOOR TOILET VENT (AT ROLLED UP WYE FITTING)
5) 1ST FLOOR LAV VERT DRAIN OUT OF WALL
6) 8D NAIL HOLE IN WASHER VERTICAL DRAIN AT BOTTOM PLATE HT. NO H20 TEST ON DWV
7) HOW MUCH BEARING IS REQUIRED AT FLOOR TRUSSES 5 1/8 GLU LAM ACROSS KITCHEN LEAVE TRUSS DRAWINGS
8) 12" PEX TO LIGHT CAN AT 1ST FLOOR ACTIVITY ROOM
9) RETRO STHD 16 AT GARAGE NOT NAILED GET EPOXY INSPECTION ON BOLT
10) BACKING AT 2ND FLOOR TUB SIDES
11) RETRO FIT STHD16 AT GARAGE NOT NAILED
12) BACKING AT 2ND FLOOR TUB
13) ? HANGER GET 16D COMMON NAIL
14) BRING BEARING PTS. FOR GIRDER TRUSS ROOF DOWN TO BOTTOM PLATE IN GARAGE/BETWEEN FLOORS, 4-2X4'S
12/13/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LATH INCOMPLETE
2) 2ND REJECTION
3) REFEE DUE
4) STOPPED INSPECTION
12/06/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*