Permit: T04CM03199

Parcel: 137060150

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
10/29/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*/ 1) TWO WAY CLEANOUT HAS BEEN INSTALLED 2) OK TO BACKFILL TRENCH
10/28/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*/1)SOIL WATER TEST IS OK. 2)NOTE; HCS CONNECTION IS OK 3)CAN NOT USE C.O. TEE WITH A EXTENSION @ TWO WAY C.O. THIS INSPECTION IS FOR ROUGH PLBG. WITHIN STRUCTURE ONLY. SHALL PROVIDE (2) DIRECTIONAL FITTINGS FOR TWO WAY C.O. 4)OK TO BACKFILL WITHIN STRUCTUE ONLY. 5)SHALL RED LINE LOCATION OF END OF LINE C.O.