Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/15/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) LEDGER LEFT OUT AT TRUSS TO WALL 10/D1 ADD A.35 FOR DOWN SHEAR AND STRAP FROM TRUSS, TO TRUSSES ON OPPOSITE SIDE OF BEAM OR WALL, H2.5 ISN'T LONG ENOUGH, THIS IS FOR DIAPHRAM WITHDRAWL TIE BOTH SIDES OF HOUSE 2) LAST INSP. MISSED CABIN TIES, INSTALL H2.5 AT ALL AREAS NOT C/TIED | |
| 09/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NAIL OFF ALL PERIMETERS 2) BLOCK ALL SCUPPERS, WEST SIDE DAMAGED OSB BLOCK BELOW, MARKED IN BLACK 3) AT DETAIL 2-10/D-1 INSTALL 2 X AT TOP CHORD HT. FOR LEDGER 4) FINISH NAILING EXT. SHEAR WEST WALL |