Permit: T04CM03177

Parcel: 141014990

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM03177

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/30/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/22/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/ 1) NEED ID NUMBER FOR H.D. USED EACH SIDE OF ( PHHD8/SD53 GARAGE) 2) MISSED P.A. REAR EAST 3) WHEN H.D. ID'D AT GARAGE, OUT DROP RUN SHEAR ON INSIDE UP TO PLATE
09/20/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/ 1) SEE ITEMS FROM LAST INSPECTION 2) WHAT BRAND NAME AND NUMBER ARE PA'S/HD AT GARAGE SO I CAN CROOS REFERENCE TO THE ONE REQUIRED ON PLAN
09/15/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*/ 1) NEED ID NUMBER FOR H.D. USED EACH SIDE OF ( PHHD8/SD53 GARAGE) 2) NAIL ROOF DECK JOINT WEST/SOUTH AREA MARKED IN BLACK 3) MISSED P.A. REAR EAST, PLAN SHOWS BEARING TO EXT. WALL GARAGE 3/26'S WEST SIDE 4) WHEN H.D. ID'D AT GARAGE, OUT DROP RUN SHEAR ON INSIDE UP TO PLATE 5) SW2 SHEAR GARAGE TO HOUSE, NEEDS TO BE BLOCKED AT TOP OF SHEAR EDGE, CONTINUE UP TO FLOOR